FR (Fire-Rated) Panel System
Key Differentiators
- NFPA 251-compliant 1-hour and 2-hour ASTM E119 fire ratings
- Integrated structure for longer spans without external support
- Tongue-and-groove joint design in SEMCO standard panels, eliminating the need for screws in the joints
- Simplified project management with factory-supplied cuts and individual panel markings
Product Details
| Applications | Casinos, Clean Rooms, Data Centers, Education, Government, Healthcare, Hospitality, Labs, Office and Commercial, Pharma |
|---|---|
| Skin Material | Galvanized steel, galvanneal, stainless steel |
| Thickness/R-Value | 4" / 7.86 BTU/HRFT2F |
| Max Height | 13' |
| Finish | Mill or field paintable |
| Fire Rating (ASTM E119) | 1-hour and 2-hour |
| Specifications | NFPA 251-compliant, Integrated structure for longer spans, Roll-formed tongue-and-groove construction, Pre-insulated joint, No screws through vertical joints, Internal media for STL and fire protection, Factory interior cuts/notches/sloped ends |
Product Overview
As the industry’s thinnest fire-rated panel, the SEMCO FR Panel System offers up to two hours of fire protection, integrated structure and superior transmission loss in an easy-to-install, tongue-and-groove design.
The FR Panel System has endured rigorous, professional, third-party testing under UL-263 “Standard for Fire Tests of Building Construction and Materials” using ASTM E119 test criteria, and it has proven to comply with the National Fire Protection Association’s® (NFPA) Code 251. The FR Panel’s significantly low thermal transfer rate offers one or two hours of added protection during a fire event, providing first-responders valuable time they need to arrive.
Key Features and Benefits
- Roll-formed tongue-and-groove construction with a fully enclosed and insulated joint to provide better fit with closer tolerances
- Pre-insulated joint, which eliminates field insulation
- No screws through vertical panel joints, lowering installation cost and eliminating the possibility of air and noise leaks that can occur with screws
- Internal media that provide excellent sound transmission loss and fire protection
- Factory interior cuts, notches, and sloped ends, as required, which reduces installation costs and accommodates equipment